Driveways & Patios
Floors & Foundations
Floors & Flatwork
Sites & Facilities
Floors & Coatings
Facilities We Serve
Site Concrete · Equipment Pads
Engineered Equipment Pads for Regina Sites
Generators, HVAC units, transformers, and site-mounted equipment all need a concrete base that's sized to their weight, positioned for their anchor bolts, and built to handle vibration. Regina Concrete designs and pours equipment pads to the equipment's specifications, not to a template. Every pad starts with the equipment cut sheet and ends with a free written estimate.
- Spec-driven pad design
- Anchor bolts templated to fit
- Vibration isolation where needed
The engineering challenge
Why Concrete Pads Fail When Undersized
A generator pad that looks solid can crack within months if it's not engineered to the actual loaded weight of the unit. Most equipment weighs more when it's full of fluids and running under load than the dry weight listed on the nameplate. A pad poured to the dry weight will settle, crack, or shift when the real load arrives.
We pull the equipment cut sheet from the manufacturer or your supplier, calculate the loaded weight (including service margin), design the slab thickness and reinforcement to carry that load, and position every anchor bolt using a template so the equipment frame bolts down without forcing or shimming. Vibration isolation gets embedded where the equipment spec requires it.
This approach applies across all our site concrete work, and equipment pads often run alongside commercial sidewalk or ADA ramp projects on the same site.
The sequence
How We Build Equipment Pads in Regina
-
Collect the equipment specs
We request the cut sheet from the equipment manufacturer or your supplier. The cut sheet tells us the footprint, loaded weight, anchor pattern, vibration class, and any isolation requirements. This drives every decision that follows.
-
Excavate and prepare the base
For exterior pads, we dig below Regina's frost line, compact the subgrade, and place a gravel base to the engineered depth. Interior pads on existing slabs may tie into the floor depending on the load and site conditions.
-
Build forms and set anchors
Forms are built to the pad dimensions, rebar is tied per the load calculations, and anchor bolts are positioned using a steel or wood template that matches the equipment's mounting frame. Vibration isolation embeds are placed if required.
-
Pour, finish, and cure
Concrete is placed and finished to the elevation the equipment expects. The pad is protected through cure, and we verify anchor bolt projection and as-built dimensions before handing off to the equipment installer.
The most common problem
Anchor Bolts Out of Position Cost Installation Time
An equipment installer arriving with a generator or HVAC unit and finding anchor bolts that don't line up with the equipment frame has a problem that can't be solved on site. Most equipment-pad disputes trace back to anchor bolt position. We template every anchor pattern from the cut sheet and verify position during the pour so the bolts land exactly where the equipment frame expects them.
Coordinate with the equipment supplier early so the cut sheet is locked in before we start forming. Equipment pads often pair with loading dock concrete or parking lot concrete work, and we sequence the whole site project to keep the install schedule on track.
Related site concrete services
Other Site Concrete Work We Do
Equipment pads is one of four site concrete services. See what else we build.
Loading Dock Slabs & Aprons
Engineered dock slabs sloped to the pit, built to handle truck loads and daily wear.
Learn moreCommercial Sidewalk Concrete
Code-compliant walks for property edges, public connections and accessible paths.
Learn moreADA Ramps & Accessible Curbs
ADA-compliant ramps, curb cuts and tactile surfaces for accessible site design.
Learn moreCommon questions
Equipment Pad Questions, Answered
Anchor patterns, vibration isolation, sizing to loaded weight and equipment-installer coordination.
HVAC pad with anchor bolts that lined up exactly with the unit frame. The HVAC installer commented that it was the easiest install he had done that month. Templating is everything.
Generator pad engineered for the unit's vibration and weight. Three years of regular generator runs, zero crack development, zero shift. The engineering held.
Transformer pad replacement during a planned outage. Coordinated the schedule tightly with the utility, pad cured and ready in the window. Power back on as scheduled. Real timing discipline.
Multiple equipment pads across a plant expansion. Every cut sheet honored, every anchor template right, every pad finished to the elevation the equipment expected. No improvisation, no surprises.
From the blog
Concrete Guides & Articles
Practical reading on planning, finishes and caring for concrete in Regina.
Ready to start
Get Your Equipment Pad Estimate
Send us the equipment cut sheet (or the unit specs) and the install location, and we will design and quote the pad in writing.
We'll assess on-site and send a written quote within one business day.